1-4 Connect to the GuardPLC Controller

Change the IP address of your programming terminal running RSLogix
Guard PLUS! software so that the GuardPLC controller and
programming terminal can communicate on a local network.

To change the IP address:

1. In Windows 2000, choose Start>Setting >Control Panel>Network

and Dial-up Connections.

2. Open Local Area Connections and click Properties. Select TCPIP

and click Properties.

3. Set the General TCP/IP Properties as shown below.

4. Confirm your settings by clicking OK in both dialog boxes.

TIP

If you suspect the GuardPLC controller has the
factory-set default IP address of 192.168.0.99 and the
default subnet mask of 255.255.252.0, set your
programming terminal’s IP address to 192.168.0.98
with a subnet of 255.255.252.0 to establish
communications.