Define safety connections – Rockwell Automation 1753-DNSI DeviceNet Safety Scanner for GuardPLC Controllers User Manual
Page 109

Publication 1753-UM002A-EN-P - July 2005
Configure Peer-to-Peer DeviceNet Communications B-7
Connections tab, RSNetWorx for DeviceNet will reject the Target
Connections file when it is imported.
3. RSLogix Guard PLUS! automatically generates a Target
Connections file within its project folder. When you use the
Automatically Update Signals option in RSNetWorx for
DeviceNet, that software automatically imports any updates
when the scanner's property page is displayed. You can also
manually export the Target Connections file to a specific
location at any time by right-clicking on the HSP Protocol and
selecting Export Target Connections.
Define Safety Connections
To define safety target connections:
1. Right-click on the HSP Protocol instance of the peer resource
and select Define Target Connections>Safety Data.
2. Drag the Safety signals from the Signal Editor to the Safety Data,
Target Signal Connections dialog.