Data entry register format selections, Data entry register format selections -6 – Rockwell Automation 2707-NP2 MICROVIEW SOFTWARE PROGRAMMING MANUAL User Manual

Page 62

Advertising
background image

Publication 2707-PM002B-EN-P

8-6 Creating Data Entry Screens

Data Entry Register Format
Selections

When inserting a data entry field, you must provide register
information that determines the address and format of the data storage
location. This section describes options available for data entry
registers.

Bit

The screen for a Bit format is shown below

Format Selection

Description

Register Number

The controller data address to be monitored.

Bit Number

The Bit number if the register number designates a
multiple bit address (a 16 bit data address, for example).
This selection is unavailable if the register number refers
to a Bit type address.

Default Value ?
Z = No Default
(Enter 1,0,Z)

This parameter defines the default value that is displayed
at the data entry position of the MicroView display. If a
default value of 1 is entered, a 1 is displayed, and the
operator is only required to press ENTER to set the bit
address.
An entry of Z defines no default value. NONE appears in
the window when Z is entered.

Advertising