Some application screens require that you specify register information.
Each DTAM screen type supports different data formats. The following table
lists each screen type and the data formats supported.
PLC Data Formats
Format
Display, Alarm,
Printer Form ➀
Screens
Data Entry
Screens
Bar Graph
Screens ➀
Background
Monitor ➀
Recipe
Screens
Bit
n
n
n
16 Bit Signed Integer
n
n
n
n
n
16 Bit Unsigned Integer
n
n
n
16 Bit BCD
n
n
n
n
n
16 Bit Hex
n
32 Bit Floating Point
n
n
n
32 Bit Unsigned Integer
n
n
n
32 Bit BCD
n
n
n
32 Bit Hex
n
ASCII
n
➀ Bar Graph, Printer Form, and Background Monitor are only available on DTAM Plus Operator
Modules.
Screen Types and
Data Formats