Bar graph screen builder – Rockwell Automation 2707-NP DTAM Programming Software User Manual

Page 90

Advertising
background image

Chapter 11

Creating Bar Graph Screens

11–2

The bar graph screen is only available on the DTAM Plus. The bar graph
Screen Builder looks like this:

Bar Graph Screen Builder Function Keys

Function

Function

Key

Designation

Function

[F1]

DISPLAY BAR

REG

Inserts data display field at the cursor point. Accesses the display
register information.

[F2]

EDIT BAR DATA

Access data register and bar graph display information.

[F3]

MAP SCREEN

Accesses screen mapping functions that link application screens
in a logical sequence.
Link screens only after all of the screens have been created.

[F4]

COPY SCREEN

Copies an existing screen to or from the current display window.
Both the source and destination screens must be of the same type
(Bar Graph screens).

[F5]

INSERT TIME

Inserts the time into the display. Only available with a DTAM Plus
having the Calendar/Clock option.

[F6]

INSERT DATE

Inserts the date into the display. Only available with a DTAM Plus
having the Calendar/Clock option.

[F7]

CLEAR SCREEN

Clears the current screen. You have the option of clearing only the
screen text or deleting the entire screen including any linking you
may have established.

[F8]

CHANGE

SCREEN

Selects another operator screen.

[F9]

SAVE

Saves the application without exiting the Screen Builder function.

[F10]

EXIT

Prompts you to save the application to the current file and exits the
DPS software.

Bar Graph
Screen Builder