Application example, Dtam plus application outline – Rockwell Automation 2707-NP DTAM Programming Software User Manual

Page 32

Advertising
background image

Chapter 3

Designing DTAM Plus and
DTAM Micro Applications

3–8

The following example shows typical menus and screens of a DTAM Plus
application. The same application could be created on a DTAM Micro with
the following exceptions:

DTAM Micro screen is 2 lines by 20 characters. Large screens would
have to be shortened or broken down into separate screens.

The DTAM Micro cannot support a bar graph screen.

DTAM Plus Application Outline

Main Menu

1. Pump/Tank Levels

2. Pump Control

3. Flow/Level Status

4. Controller Status

Security

* Restricted Access *
Enter Your Security
Code: * * * * * * * *

Data Entry

East Tank: 38% Full
Setpoint is 280 CFM
Please Enter New
Setpoint: 145

Data Entry

West Tank: 72% Full
Setpoint is 170 CFM
Please Enter New
Setpoint:

Data Display

East Pump:

280 CFM

West Pump:

0 CFM

North Pump:

207 CFM

South Pump:

70 CFM

Data Display

Controller Status
Scan Time is: 7 ms
Controller is: Online
Battery Power: OK

Data Display

West Feed Pump
Main Pump is: Off
Fill Rate: 8 CFM
Tank is 72% Full

Sub Menu

1. East Pump/Tank
2. West Pump/Tank

Data Display

Data Display

East Feed Pump
Main Pump is: On
Fill Rate: 280 CFM
Tank is 38% Full

Data Display

West Feed Pump
Efficiency: 83%
Run Time: 22 Hrs.
Next Serv: 978 Hrs.

Data Display

East Feed Pump
Efficiency: 77%
Run Time: 693 Hrs.
Next Serv: 307 Hrs.

Bar Graph

Tank Total Pumping
Rate is: 557 CFM

East Tank:

38% Full

West Tank:

72% Full

North Tank:

16% Full

South Tank:

5% full

Application Example

Advertising