Description of the application tags, Dh-485, dh+, and df1 application tags, Remote i/o application tags – Rockwell Automation 2711-ND3 PanelBuilder32 Quick Start Manual User Manual

Page 64

Advertising
background image

64

Publication 2711-QS003D-EN-P - June 2009

Chapter 5 Entering Application Tags

Description of the
Application Tags

DH-485, DH+, and DF1 Application Tags

The table shows application tags used by the DH-485, DH+, and DF1
applications. Defaults are accepted for fields not shown in table.
These tags are also used for EtherNet/IP (to a PLC-5E or SLC) and
ControlNet (to a PLC-5C).

Remote I/O Application Tags

The table shows application tags used by the Remote I/O application.
Defaults are accepted for fields not shown in table.

Tag Name

Data Type

Tag
Address

Description

Node
Name

Initial
Value

Min

Max

Start_Motor

Bit

B3:0/0

Starts the motor

LC_1

0

0

0

Stop_Motor

Bit

B3:0/1

Stops the motor

LC_1

0

0

0

Motor_Status_Ind

Bit

B3:0/2

Shows on/off motor status

LC_1

0

0

0

Motor_Speed

Unsigned
Integer

N7:0

Shows the motor speed

LC_1

0

0

65535

Set_Max_Motor_Speed

Unsigned
Integer

N7:1

Sets the maximum speed

LC_1

1800

600

1800

Speed_Alarm

Bit

B3:1/0

Triggers alarm messages

LC_1

0

0

0

Tag Name

Data Type

Tag
Address

Description

Node
Name

Initial
Value

Min

Max

Start_Motor

Bit

I

:010/0

Starts the motor

LC_1

0

0

0

Stop_Motor

Bit

I

:010/1

Stops the motor

LC_1

0

0

0

Motor_Status_Ind

Bit

O:010/0

Shows on/off motor status

LC_1

0

0

0

Motor_Speed

Unsigned
Integer

O:011

Shows the motor speed

LC_1

0

0

65535

Set_Max_Motor_Speed

Unsigned
Integer

I

:011

Sets the maximum speed

LC_1

1800

600

1800

Speed_Alarm

Bit

O:012/0

Triggers alarm messages

LC_1

0

0

0