Configuring FactoryTalk Historian Chapter 5
Rockwell Automation Publication HSE-IN025A-EN-E–September 2013
107
If the server name is not listed, do the following:
1. On the Server menu, click Add Server. The Add Server
dialog box appears.
2. In the Network Node text box, type the fully qualified
domain name (FQDN) of the server.
3. Clear the Confirm check box, and click OK. The new
server is added to the server list.
This allows a remote client connection to be established
with the FactoryTalk Historian SE server.
4. Close the Connection Manager.
4. Under System Management Tools, select Security >
Mappings & Trusts.
5. Verify that
PIBuffSubSystemService is listed in the Trusts tab.
6. Exit the System Management Tools.
7. Go to
Start > All Programs > Rockwell Software > FactoryTalk
Historian SE > Interface Configuration Utility. The Interface
Configuration Utility dialog box appears.
8. From the Interface list, select the name of the FactoryTalk
Historian Live Data Interface.
9. On the Tools menu, click Buffering. The Buffering dialog
box appears.