Configuring FactoryTalk Historian Chapter 5

Rockwell Automation Publication HSE-IN025A-EN-E–September 2013

107

If the server name is not listed, do the following:

1. On the Server menu, click Add Server. The Add Server

dialog box appears.

2. In the Network Node text box, type the fully qualified

domain name (FQDN) of the server.

3. Clear the Confirm check box, and click OK. The new

server is added to the server list.
This allows a remote client connection to be established
with the FactoryTalk Historian SE server.

4. Close the Connection Manager.

4. Under System Management Tools, select Security >

Mappings & Trusts.

5. Verify that

PIBuffSubSystemService is listed in the Trusts tab.

6. Exit the System Management Tools.
7. Go to

Start > All Programs > Rockwell Software > FactoryTalk

Historian SE > Interface Configuration Utility. The Interface
Configuration Utility
dialog box appears.

8. From the Interface list, select the name of the FactoryTalk

Historian Live Data Interface.

9. On the Tools menu, click Buffering. The Buffering dialog

box appears.