E 60) – Rockwell Automation FactoryTalk Historian SE 4.0 Installation and Configuration Guide User Manual

Page 60

Advertising
background image

Chapter 4 Post-Installation Tasks

60

Rockwell Automation Publication HSE-IN025A-EN-E–September 2013

<add key="streamedPort" value="5459"/>

To enable encrypted communication, add

encrypt=Yes;

to

the code. See the Microsoft SQL Native Client
documentation for other options.

4. If the AF application service is running, stop and restart it for

your changes to take effect.

If you need to direct your AF application service to a different AF

SQL database, follow the instructions below to specify a new SQL
Server instance and to enable communications.

To specify a new SQL Server instance and enable
communications:

1. On the AF application service computer, edit the

AFService.exe.config

file in the

PIPC\AF

folder and replace

the server information with the name of the remote SQL

Server to be accessed.

2. Restart the AF application service computer.
3. If the AF application service is using the NetworkService or

LocalSystem account, add the Domain\Machine Name for the
remote AF server to the local AFServers Windows group (on
the AF SQL database computer.)

4. If the AF application service has been modified to use any

other account, add the account under which it is running to
the local AFServers Windows group (on the AF SQL database
computer.)
For details, see "Create the AFServers Local Group on the AF
Application Service Computer (page 56)", step 3.

5. Restart the AF SQL database computer.

Configure AF Application
Service to Point to a Different
AF SQL Database

Advertising