Chapter 5 Configuring FactoryTalk Historian

86

Rockwell Automation Publication HSE-IN025A-EN-E–September 2013

<GeneralLicensePool> = ∑ <PTY3 licenses> +
<BaseLicenseCount> + ∑ <FHSE3ADD licenses>

<GeneralLicensePool> = 500 + 2400 + 2000
<GeneralLicensePool> = 4900

In this example, the total of 19500 licenses has been distributed in
the following way:

Licenses and license pools

Values

License total

19500

Rockwell license pool

14600

General license pool

4900

TIP

The symbols used in the formulas presented below, mean the following:

"the sum of"

Min "the lower value of the two in the brackets"
Max "the greater value of the two in the brackets"

In the following example we will calculate how licenses will be
distributed between the General and Rockwell license pools without
FHSE3ADD license activations.

We will use the following values:

Activation

Value

∑ (sum)

FHSE.2K

2000

12000

FHSE.10K

10000

FHSE3ADD.2K

0

0

FHLD.5K

5000

5000

PTY3.500

500

500

Total

17500

Distributing Licenses
without FHSE3ADD