Distributing licenses without fhse3add activation – Rockwell Automation FactoryTalk Historian SE 4.0 Installation and Configuration Guide User Manual
Page 86

Chapter 5 Configuring FactoryTalk Historian
86
Rockwell Automation Publication HSE-IN025A-EN-E–September 2013
<GeneralLicensePool> = ∑ <PTY3 licenses> +
<BaseLicenseCount> + ∑ <FHSE3ADD licenses>
<GeneralLicensePool> = 500 + 2400 + 2000
<GeneralLicensePool> = 4900
In this example, the total of 19500 licenses has been distributed in
the following way:
Licenses and license pools
Values
License total
19500
Rockwell license pool
14600
General license pool
4900
TIP
The symbols used in the formulas presented below, mean the following:
∑
"the sum of"
Min "the lower value of the two in the brackets"
Max "the greater value of the two in the brackets"
In the following example we will calculate how licenses will be
distributed between the General and Rockwell license pools without
FHSE3ADD license activations.
We will use the following values:
Activation
Value
∑ (sum)
FHSE.2K
2000
12000
FHSE.10K
10000
FHSE3ADD.2K
0
0
FHLD.5K
5000
5000
PTY3.500
500
500
Total
17500
Distributing Licenses
without FHSE3ADD
Activation