Error number

Description

200

The user has declined to make the changes to the
configuration of Windows Firewall.

320

The network connection specified in WFCU could not be
found.
Cause: No network connection is configured.
Resolution: Configure the network connection and then
configure Windows Firewall.

See "Configuring Windows Firewall with WFCU (page 121)"

for details.

• The errors that may appear if you use another firewall utility to

configure network security on the computer with FactoryTalk
Historian installed:

Error number

Description

10

The version of Windows Firewall is not supported by WFCU.

100

Some parameters of the WFCU configuration are missing.

110

Some parameters of the WFCU configuration are incorrect.

120

The .WFCU file contains incorrect data.

130

The .WFCU file is missing.

300

The configuration of Windows Firewall is not supported by
WFCU.

310

The .WFCU file contains incorrect configuration settings.

400

The Microsoft Firewall service is stopped.

-999

Rockwell Windows Firewall Configuration Utility (WFCU)
could not be found.

See "Configuring Firewall for FactoryTalk Historian (page

75)" for details.

If the error message does not contain the error number, refer to the
FactoryTalk Historian log for the error details.