Chapter 5 Configuring FactoryTalk Historian

76

Rockwell Automation Publication HSE-IN025A-EN-E–September 2013

documentation of your firewall configuration utility for more
information.

NOTE

You need administrator privileges to perform the steps described below.

To manually configure the firewall:

• Open TCP/IP ports in the firewall to accept incoming

connections:
See the table below to learn which ports need to be open for
individual FactoryTalk Historian suites.

For this FactoryTalk
Historian suite:

Open these ports:

Of this type:

Historian to Historian
Interface

5450

TCP

Asset Framework

5457
5459

TCP
TCP

Historian Server

5450
5454
5455
5456
5458

TCP
TCP
TCP
TCP
TCP

Live Data Interface

6000

TCP

• Allow FactoryTalk Historian Live Data Interface to

communicate through the firewall:
See the table below to learn which settings you need to use
when configuring the firewall.

Item

Description

The absolute path to
the Live Data

interface

<PIHOME_Value>Interfaces\LDInterface\FTLDInt.exe,
where <PIHOME_Value> is the path specified in the

following registry key:
Computer > HKEY_LOCAL_MACHINE > Software >
Wow6432Node > PISystem

The name (ID) of the
Live Data interface

PIUniint Interface to the PI System.