Appendix B Configuring the Advanced Server Components
144
Rockwell Automation Publication HSE-IN025A-EN-E–September 2013
To verify the Notifications status in the Administrative Tools:
1. Go to
Start > Administrative Tools > Services. The Services
dialog box appears.
2. In the right pane, find the PI Notifications Scheduler service.
3. Make sure that its status reads Started.
To verify the Notifications status in the System Management
Tools:
1. Go to
Start > All Programs > Rockwell Software > FactoryTalk
Historian SE > System Management Tools. The System
Management Tools dialog box appears.
2. Under Collectives and Servers, select the Historian server
whose data you want to check.
3. Under System Management Tools, select Operation >
Network Manager Statistics.
4. In the right pane, find the following services:
• PINotificationsManager.exe
• PINotificationsHistoryProvider.exe
The connection status (ConStatus) for these services should
be [0] Success.
To create and configure a module database attribute:
1. Go to
Start > All Programs > Rockwell Software > FactoryTalk
Historian SE > System Explorer. The PI System Explorer
dialog box appears.
2. On the File menu, click Connections. The Servers dialog box
appears.
Verify the Notifications
Status
Create Module Database
Attributes