Input/output circuit description 2-7 – Rockwell Automation T6200 Compressor Anti-Surge and Capacity Controller User Manual

Page 19

Advertising
background image

Input/Output Circuit Description

2-7

1A

Microprocessor

4.7K

Input to

Backup ControlBoard

Microprocessor

100V

100V

1A

1A

Input to

1.8K

Primary Control Board

1.8K

4.7K

100V

1A

100V

Termination

Panel

Power

4.7K

100V

1A

1A

1A

1A

Termination

Panel

100V

24 VDC

Input to

Primary Control Board

Microprocessor

1.8K

Backup Control Board

Regulator

Voltage

4.7K

24 VDC

Input to
Microprocessor

1.8K

Regulator

Voltage

Discrete Input with
Excitation from
Controller

FIGURE 2-6.

Isolated Discrete
Input

FIGURE 2- 5.