Metrohm tiamo 2.1 Manual User Manual
Page 544

5.6 Commands
■■■■■■■■■■■■■■■■■■■■■■
530
■■■■■■■■
tiamo 2.1
Window = Time
Range
0 ... 999999 s
Default value
0 s
Upper limit
Value for the upper limit of the window.
Window = Measured value
Range
-200.0 ... 200.0 µA
Default value
200.0 µA
Window = Volume
Range
0.00000 ... 9999.99 mL
Default value
9999.99 mL
Window = Time
Range
0 ... 999999 s
Default value
999999 s
Gran evaluation
Note
This evaluation method is possible only with Titrando and 855.
Gran evaluation
on | off (Default value: off)
If this option is enabled, then titration curves will be evaluated in accordance
with the Gran Plot procedure(see Chapter 5.6.3.9.4, page 856).
Initial volume
Volume which is present in the measuring vessel before the command is
started.
Range
0.01 ... 9999.99 mL
Default value
50.00 mL
Lower limit
Value for the lower limit of the Gran evaluation range.
Range
-200.0 ... 200.0 µA
Default value
-200.0 µA