164 CyberSWITCH

calls. The system will not accept or make a call when the added bandwidth will exceed the
configured maximum. The value is configured as a number from 2,400 bps to 3,072,000 bps. You
may configure any value in this range. For example, if you have configured the base data rate at
64,000 bps, and the maximum data rate at 512,000 bps, the system would use a maximum of eight
calls (connections) running in parallel to open up bandwidth (512,000 / 64,000 = 8). The value need
not be a multiple of the Base Data Rate. The default configuration for the maximum data rate is
128,000 bps.

Note:

A condition may occur in which the number of connections has reached the point where
the maximum data rate will be exceeded with the next additional connection, and yet the
remote device may initiate another call to the system. This inbound call causes the
maximum data rate to be exceeded and the system will drop a connection. If the remote
device is auto-dialing, this flip-flop condition will continue until you manually correct the
problem. To correct this problem, configure the Throughput Monitor information to be
identical on the CyberSWITCH and the remote device, or disable Throughput Monitoring
on one of the devices. The Internet Engineering Task Force (IETF) is working on a standard
solution to this problem.

If you are using multiple connections running in parallel (i.e., to the same device), the
maximum number of connections that can be aggregated is 32. For maximum performance,
however, we recommend aggregating no more than eight connections at a time.

D

IAL

-O

UT

P

HONE

N

UMBER

(

S

)

This configuration element is required when the Dial-Out feature is used. The dial-out capability
allows the CyberSWITCH to initiate connections to PPP or HDLC devices located at remote sites.
A phone number must be defined for each remote device that will be dialed. This number includes
any prefix digits, area codes, or extensions as required to dial the destination device. It is possible
to specify eight phone numbers for the remote device.

The system dynamically controls the bandwidth in use between the system and other devices. This
is accomplished by establishing and disconnecting up to 8 calls to a single remote site over the
digital network. The system monitors the connections for utilization and will add and remove
connections based on the device configurable parameters described above (Base Data Rate, Initial
Data Rate, and Maximum Data Rate).

S

UBADDRESS

The Subaddress is used by a CyberSWITCH when it attempts to make a connection to a remote
device. A Subaddress allows the device to share a telephone number with other devices and yet still
recognize calls destined for it.

P

ROFILE

N

AME

The device profile identifies which line or lines are reserved for a particular profile, which in turn
are reserved for a particular device(s). The feature that uses this configuration element,

Bandwidth

Reservation

, is described in detail, in the Configuring Call Control chapter.

Advertising