Cabletron Systems CSX1000 User Manual

Page 480

Advertising
background image

USER’S GUIDE

480 CyberSWITCH

The call is allowed to continue
A call has been up longer than the amount of time configured, but it has not been taken down.

The compression subsystem is not enabled
Check CFGEDIT; verify that compression is enabled.

The conformance selection is prior to CCITT 1988
Verify that the facilities provided by the service provider are CCITT 1988.

The RADIAC Feature is no longer supported. The RADIAC feature has been replaced by the TACACS
Feature. The TACACS Feature configuration must be completed before usage.
With the addition of User Level Security, the need for the RADIAC GATEWAY is gone. The
CyberSWITCH has incorporated the functionality of the RADIAC GATEWAY within the
CyberSWITCH itself. When the configuration file parser encounters a system configured for using
the RADIAC feature, it switches the configuration to now use User Level Security utilizing a
TACACS off-node authentication server. Since the older CyberSWITCH knew nothing about the
location of the TACACS server, the TACACS server configuration must be completed before the
CyberSWITCH will allow network access through a WAN connection.

Timeout detected on connection establishment
The system initiated a connection with a remote site, but a time-out occurred while waiting for a
connection response from the network. Verify that the remote site is active and that the network is
operational.

Timeout detected on receiving caller’s number
The incoming call security feature is enabled and the caller’s number was not received, so the call
was disconnected. Contact your phone company and verify that your switch supports passing
along the calling number information element. (This is sometimes referred to as ICLID for
InComing Line Identification).

Timeout on SPID Exchange - Slot=<slot# > Port=<port # > Ces=<communication endpoint suffix>
SPID exchange was not completed in time (i.e., switch never responded to the SPID). Check switch
configuration to make sure the correct SPID value has been entered.

Timeout on Startup Complete
A startup complete message was not return from the Combinet after we sent the response a number
of times. Check the configuration, and then reboot the Combinet. If problem persists, contact your
Distributor or Customer Support.

Timeout waiting for DL Config Response
Timeout waiting for DSL Config Response
Timeout waiting for Terminate DSL Response
The above messages indicate that an attempt has been made to dynamically update the Data Link
configuration, but the system did not receive a response from a Basic Rate adapter for an earlier
request. Restart the system and review the configuration for the adapter. If the problem persists,
the system may be faulty. Contact your Distributor or Customer Support.

Tried to free unallocated buffer <sub name>, size=<size>
Internal error that should be reported to Customer Support.