Remote device connectivity, Remote device connectivity 389 – Cabletron Systems CSX1000 User Manual

Page 389

Advertising
background image

Workgroup Remote Access Switch 389

P

ROBLEM

D

IAGNOSIS

Remote Device Connectivity

R

EMOTE

D

EVICE

C

ONNECTIVITY

Problem:
A remote device is not able to connect to the CyberSWITCH.

Set-up:
The system software should be up and running. (At the administration console: if you are in the
Connection Monitor window, exit to the “[

System Name

] >” prompt.)

1.

Enable the call trace messages with the

trace on

console command.

2.

Erase the current system messages using the

er

console command.

3.

In a controlled manner, initiate an ISDN connection from the remote device.

Action:
1.

After a connection has been initiated, view the system messages (display system messages by
issuing the

dr

console command). Look for the following call request messages among the

system messages:

In - INCOMING CALL Call Id=<call Id> Slot =<slot #> Port=<port #> Chans=<bearer

channel map> Ces=<comm endpoint suffix> Rate=<data rate>

Out - CONNECT Call Id=<call Id> Slot=<slot #> Port=<port #> Chans=<bearer

channel map> Ces=<communication endpoint suffix> ConnId=<connect Id>

In - CONNECT Call Id=<call Id> Slot=<slot#> Port=<port #> Chans=<bearer channel

map> Ces=<communication endpoint suffix> ConnId=<connect Id>

If the system reports these messages, then continue with the next step.

If the system does not report these messages, the remote device is not correctly connecting to
the system. Check and verify the configuration of the remote device.

2.

If the system displays the following message among the system messages (display system
messages by issuing the

dr

console command),

Security Rejection-Invalid Calling Line Id - <#>

the network is indicating a calling line identifier that is not configured for any valid device in
the system Device list. The number “# ” indicates the actual number presented by the network.

3.

For Remote Bridge Devices:
If the system displays the following messages among the system messages,

Security Rejection - Caller did not negotiate security

Security Rejection - No Bridge Address given by caller

Security Rejection - Unknown Calling Bridge

Security Rejection - No Password given by caller

Security Rejection - Invalid Password given

Security Rejection - HDLC not supported by the caller

review the system configuration for the Device List. You can also refer to the

System Messages

chapter for the message meanings and the appropriate actions to be taken.

4.

For IP Host Devices:
If the system displays the following messages among the system messages:

IP Call Dropped: ID_RSP was not received from remote

IP Call Dropped: XID was not received from remote