Cabletron Systems CSX1000 User Manual

Page 344

Advertising
background image

USER’S GUIDE

344 CyberSWITCH

example 2:

Chicago-Schaumburg 00000001 CONNECT 1 OF 3 MonroeCounty PORT 1/1/1
Chicago-Schaumburg 00000001 CONNECT 2 OF 3 OUT TO 3135551212
Chicago-Schaumburg 00000001 CONNECT 3 OF 3 64Kb 08/16/95 23:11:55

Note:

In most cases, a device is identified when a connect event occurs and the device name is
included in the connect report. With user level security, the connect event occurs before the
user is identified. Therefore, the connect report will contain a name of UNKNOWN. The
disconnect report will have the actual user name, as determined by SENTRY. The
connection Id from the connect and disconnect reports will match.

Disconnect Event Report Contents

On a disconnect event, records 1 through 4 are used. The event type is DISCONNECT. The
timestamp reflects the time that the decision to disconnect was made. The phone number displayed
is the phone number in the Connect report.

The duration is calculated by subtracting the connect event time from the disconnect time.

The following is an example disconnect event report:

Chicago-Schaumburg 00000001 DISCONNECT 1 OF 4 MonroeCounty PORT 1/1/1
Chicago-Schaumburg 00000001 DISCONNECT 2 OF 4 IN FROM 3135551212
Chicago-Schaumburg 00000001 DISCONNECT 3 OF 4 64Kb 08/16/95 23:11:55
Chicago-Schaumburg 00000001 DISCONNECT 4 OF 4 DURATION 01:11:55

Reject Event Report Contents

On a reject event, records 1 through 4 are used. The event type is REJECT. The timestamp reflects
the time that the decision to disconnect was made. An incoming phone number is displayed if it is
provided by the telephone switch. Not all switches provide calling line identification. A phone
number is always displayed for outbound calls.

The duration is calculated by subtracting the ISDN connection timestamp (the time that the ISDN
connect message was received from the switch) from the reject event timestamp.

The following is an example reject event report:

Chicago-Schaumburg 00000001 REJECT 1 OF 4 UNKNOWN PORT 1/1/1
Chicago-Schaumburg 00000001 REJECT 2 OF 4 IN FROM 3135551212
Chicago-Schaumburg 00000001 REJECT 3 OF 4 64Kb 08/16/95 23:11:55
Chicago-Schaumburg 00000001 REJECT 4 OF 4 DURATION 00:00:07

System Up Event Report Contents

On a System Up event, only record 1 is used. The event type is SYSTEM UP. No data is filled in for
the Remote Device Name field or the Port field.

The following is an example reject event report:

Chicago-Schaumburg SYSTEM UP 1 OF 1

Advertising
This manual is related to the following products: