Dedicated Connections

6.

If the above actions fail to correct the problem, then call your phone company (carrier) to check
the status of the line. If it is determined that there is no problem with the line, contact Customer
Support.

Problem:
A WAN line is unavailable, and the following two messages are displayed together (to display
messages, issue the

dr

console command):

WAN card in slot <slot #> signals it is operational

Abnormal response rcvd: state=-1 msg=73 reason=6 cc state=-1

Action:
1.

Check the configuration. Verify that all lines are configured with corresponding data links. If
this is not the case, add data links to all configured lines.

D

EDICATED

C

ONNECTIONS

Problem:
A dedicated connection is not functioning.

Action:
If the dedicated connection is not up, this usually indicates that the device could not be validated
for some reason. Check the configuration for the device that will be using the dedicated connection,
and make any necessary corrections.

F

RAME

R

ELAY

C

ONNECTIONS

Problem:
The system displays the following message in the report log.

Unexpected error during transmission of LMI frame

Action:
Start up the run-time configuration utility CFGEDIT by entering the following console command:

cfgedit

For the Frame Relay access, change the Frame Relay LMI type.
Save the configuration change, and restart the system.

Problem:
The system displays one of the following message in the report log.

[FR_IETF] Authentication Failure of remote device “NAME”

[FR_IETF] Off-node Authentication Failure of remote device “NAME”

Action:
The device indicated device database does not have a device entry corresponding to the permanent
virtual circuit. Start up the run-time configuration utility CFGEDIT by entering the following
console command:

cfgedit

For the Frame Relay PVC, change the PVC name to match the remote device name.