Cabletron Systems CSX1000 User Manual

Page 449

Advertising
background image

Workgroup Remote Access Switch 449

S

YSTEM

M

ESSAGES

System Message Summary

Failed to obtain Terminal info in smgr_proc_terminal_auth_sess 0
A session control block was not found for this authentication session. Contact your Distributor or
Customer Support.

Failed to start a Terminal Auth session. Device + User level Security not enabled
A terminal mode connection was received and Device + User level security was not enabled. Verify
correct security settings and default async protocol settings.

FAILED XMODEM INITIALIZATION
The UART controlling the Console Information Port (CIP) could not be initialized. The system will
automatically reset and attempt a reboot in an effort to correct the problem. If the system continues
to fail, make note of the displayed messages, and contact your Distributor or Customer Support. A
software update is likely needed.

FAILED XMODEM SESSION
The X-Modem session did not successfully terminate. Likely causes include exhausting timeout
limits and noisy lines. The system will automatically reset and attempt a reboot in an effort to
correct the problem. If the system continues to fail, make note of the displayed messages, and
contact your Distributor or Customer Support. A software update is likely needed.

Failure during read of file <file name> for WAN card in slot <slot # >
If seen repeatedly, the above message indicates a problem with your hard drive. Contact your
Distributor or Customer Support.

Failure during read of file ’s’
The WAN card initialization subsystem encountered an error reading the file indicated. Check for
proper software installation.

Failure during Static RAM test on adapter # ’x’
The WAN card bootstrap program encountered an error during the Static RAM test. This indicates
that the adapter card may be faulty. Contact your Distributor or Customer Support.

Failure on closure of file <file name>
Failure on file closure <file name>
Failure on write of file <file name>
Failure opening file <file name>
If seen repeatedly, the above messages indicate a problem with your hard drive. Contact your
Distributor or Customer Support.

Failure to allocate enough memory for XILINX load file
The WAN card initialization subsystem failed to allocate a buffer for use in downloading files.
Restart the system. Report the problem if it continues.

File=l2, Fn=<func name>, err=Layer 2 Error<err msg>, port=<port# >, CES=<link Id>
A Layer 2 error was encountered on the indicated BRI link or port. Your ISDN line (data link) may
be going down. If this error condition persists, contact your Distributor or Customer Support.
Below are possible error messages and their corresponding definitions:

DISC rcvd
The Network has sent a Layer 2 DISC (Disconnect), terminating the data link. An attempt
will be made to re-establish the data link after a switchtype-dependent delay.

Advertising
This manual is related to the following products: