Workgroup Remote Access Switch 485

S

YSTEM

M

ESSAGES

System Message Summary

X25 facilities error, reverse charging not accepted
The reverse charging facility was selected by the DTE. Verify that reverse charging is enabled by
both DTE’s and the service provider.

X25 facilities error, fast select not available
The fast select facility was selected by the DTE. Verify that fast select is enabled by both DTE’s and
the service provider.

X25 facilities error, fast select not accepted
The fast select facility was selected by the DTE. Verify that fast select is enabled by both DTE’s and
the service provider.

X25 facilities error, throughput negotiation not allowed
The DTE throughput class does not match the throughput class available at either the DCE or the
remote DTE, and throughput negotiation is not enabled. You should enable throughput
negotiation at both DTE’s. If this is not possible, or does not work, select the same throughput class
at both DTE’s.

X25 facilities error, closed device group not allowed
The closed device group facility was selected by the DTE. Verify that the closed device group
facility is enabled by both DTE’s and the service provider.

X25 facilities warning, reverse charging info not available
The service provider does provide reverse charging information. No action required.

X25 facilities error, facility not available
A facility was requested which is not enabled. Verify that the specific facility is enabled by both
DTE’s and the service provider.

X25 facilities error, packet length negotiation not allowed
The DTE packet length does not match the packet length available at either the DCE or the remote
DTE, and packet length negotiation is not enabled. You should enable packet length negotiation at
both DTE’s. If this is not possible, or does not work, select the same packet length at both DTE’s.

X25 facilities error, window size negotiation not available
The DTE window size does not match the window size available at either the DCE or the remote
DTE, and window size negotiation is not enabled. You should enable window size negotiation at
both DTE’s. If this is not possible, or does not work, select the same window size at both DTE’s.

X25 facilities error, RPOA not available
Recognized Private Operating Agency selection is not available. The System does not support this
feature.

X25 facilities warning, transit delay not available
The service provider does provide transit delay information. No action required.

X25 facilities warning, charge inform not available
The service provider does provide charging information. No action required.

X25 facilities warning, call redirect notification not available
The service provider does provide call redirect information. No action required.