Cabletron Systems CSX1000 User Manual

Page 484

Advertising
background image

USER’S GUIDE

484 CyberSWITCH

WAN: RBS Not Available on this card.
A RBS debugging command was attempted on a PRI card that is not configured for RBS. Check the
card configuration and ensure you have the proper type of card.

Watchdog timeout detected on DM board in slot <slot # >
The Digital Modem card in the specified slot is not functioning properly. Check the board’s
configuration in CFGEDIT, reseat the board in its ISA slot, and check any MVIP bus cabling. If
everything seems in order and the problem persists, contact your Distributor or Customer Support.

Watchdog timeout detected on WAN board ’x’
The system has detected that the indicated adapter has failed. This is a fatal condition and will
cause the card to be reset. Verify the

settings

on the adapter. If theses are all correct and the problem

persists, the indicated adapter card may be faulty. Contact your Distributor or Customer Support.

The following messages are reported when a remote X.25 device's facilities do not match with those
configured locally:

X25 facilities error, facilities not allowed in PVC
A facility is configured, for example call deflection, which is not allowed in a PVC. Check your PVC
configuration.

X25 facilities error, fast select with restriction on response was required
The fast select with restriction on response is required. Verify that fast select is enabled by both
DTE’s and the service provider.

X25 facilities error, bad facility length
The facilities length is missing. Contact your Distributor or Customer Support.

X25 facilities error, invalid facilities length
The length of the facilities packet is invalid. Contact your Distributor or Customer Support.

X25 facilities error, invalid DTE address
The supplied address in a X.25 call packet was invalid. Verify that the local DTE address
configuration matches the address supplied by the service provider.

X25 facilities error, facility not allowed
A facility was requested which is not enabled. Verify that the specific facility is enabled by both
DTE’s and the service provider.

X25 facilities error, facility length too short
The length of the facilities packet is too short. Contact your Distributor or Customer Support.

X25 facilities error, invalid facilities parameter
A value was chosen for facility which is out of the acceptable range of values for that facility. The
range of acceptable values for that facility should be verified at both DTE’s and by the service
provider.

X25 facilities error, reverse charging not allowed
The reverse charging facility was selected by the DTE. Verify that reverse charging is enabled by
both DTE’s and the service provider.