Cabletron Systems CSX1000 User Manual

Page 475

Advertising
background image

Workgroup Remote Access Switch 475

S

YSTEM

M

ESSAGES

System Message Summary

SSB: Post 28 i960lan_82596sx FAILURE
The i960 failed its LAN Coprocessor test. The boot process should continue; however, make note of
the error message in the event of a future problem.

SSB: Post 29 i960lan_82503 FAILURE
The i960 failed its LAN transceiver test. The boot process should continue; however, make note of
the error message in the event of a future problem.

SSB: Post 30 i960per_mod_mem_1 FAILURE
The i960 failed its peripheral buffer memory test using the first test pattern. The boot process
should continue; however, make note of the error message in the event of a future problem.

SSB: Post 31 i960per_mod_mem_2 FAILURE
The i960 failed its peripheral buffer memory test using the second test pattern. The boot process
should continue; however, make note of the error message in the event of a future problem.

SSB: Post 32 i960hdlc_1 FAILURE
The i960 failed its 80532 test using the first HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.

SSB: Post 33 i960hdlc_2 FAILURE
The i960 failed its 80532 test using the second HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.

SSB: Post 34 i960hdlc_3 FAILURE
The i960 failed its 80532 test using the third HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.

SSB: Post 35 i960hdlc_4 FAILURE
The i960 failed its 80532 test using the fourth HDLC controller. The boot process should continue;
however, make note of the error message in the event of a future problem.

SSB: Post 36 i960isdn_1 FAILURE
SSB: Post 37 i960isdn_2 FAILURE
SSB: Post 38 i960isdn_3 FAILURE
SSB: Post 39 i960isdn_4 FAILURE
The i960 failed its 2086 test using the first (second, third or fourth) D-channel controller The boot
process should continue; however, make note of the error message in the event of a future problem.

SSB: Timed out waiting for i960 to initialize for POSTSs
The i960 did not respond to an initialization request in a timely manner. This is a i960 failure. The
boot process should continue; however, make note of the error message in the event of a future
problem.

Starting Triggered RIP/SAP for <device>
This message indicates that triggered RIP/SAP has started for a device (either locally configured
or one present in the WAN peer list). Triggered RIP/SAP has been configured as a routing protocol
for this particular device.

Stream Ready rejected - MTU too small
The remote device will only accept the stream connection if the MTU is set to be > 1514. Check to
make sure that the remote device and the CyberSWITCH MTU value is set to > 1514.

Advertising
This manual is related to the following products: