Spanning tree messages, Warning messages, Error messages – Cabletron Systems CSX1000 User Manual

Page 428: System message summary, Spanning tree messages 428

Advertising
background image

USER’S GUIDE

428 CyberSWITCH

S

PANNING

T

REE

M

ESSAGES

The Spanning Tree protocol is only supported by the Ethernet-2 interface card.
Spanning Tree protocol messages are prefaced with [STP]. During normal operation, when
Spanning Tree protocol is enabled, the system may report informational messages such as:

[STP] A new Root Bridge has been detected

[STP] LAN Port <port #> is now a Designated Port

W

ARNING

M

ESSAGES

System warning messages signal events that you should investigate. These messages may be
normal during certain network conditions, or they may indicate a problem. The system should
continue to operate after posting a warning message. If the system fails to operate normally, then
report it using the problem report form included in

Getting Assistance.

E

RROR

M

ESSAGES

When the system detects errors, it reports error messages. If the faulty component cannot be
identified, and an error condition persists, then report the error by using the problem report form
included in

Getting Assistance

.

S

YSTEM

M

ESSAGE

S

UMMARY

The following pages list all the informational, warning and error messages alphabetically. The text
describes the messages, and includes suggestions for problem resolution (if applicable). Note that
the trace messages have been isolated for your convenience, and are summarized in the next
chapter.

<timestamp> # 000: Couldn’t open the file C:\SYSTEM\PLATFORM.NEI
The open operation failed, no further detail is available.

<timestamp> # 0000: Error reading C:\SYSTEM\PLATFORM.NEI
The read operation failed, perform a software upgrade to reinstall the file.

<timestamp> # 0000: Error reading platform type: there is no “plat name” field
There is no <platform name> value following the “=” character in the “current setting” string.

<timestamp> # 0000: Error reading platform type: there was no “=” in the string
The “current setting” string has the format “<platform type>=<string>”. This error message
indicates that no “=” character exists in the string.

<timestamp> # 0000: Error reading platform type: type value is too large
The <platform type> value in the “current setting” string is too large to represent an actual platform
type.

<timestamp> # 0000: Error reading platform type: type was not converted to an int
The <platform type> value in the “current setting” string could not be converted to an actual