System Message Summary

DM upgrade success. Board=<board # >, Modem=<modem # >
The system has successfully updated the firmware of the specified modem on the Digital Modem
card.

DM: TimeSlot driver circuit id already in use on CREATE
DM: No TimeSlot driver circuits available for CREATE
DM: TimeSlot driver circuit id not in use on REMOVE
DM: TimeSlot driver circuit id not found on REMOVE
There were problems related to the Digital Modem’s use of the TDM bus. Contact your Distributor
or Customer Support.

Downloading Bootstrap to DM card in slot <slot # >
Informational message stating that the system is attempting to initialize a Digital Modem card.
Watch for subsequent log messages to ensure the initialization is successful.

Downloading DM card in slot <slot # > with operational software
Informational message displayed during a successful initialization. Watch for subsequent log
messages to ensure the initialization is successful.

Downloading WAN card in slot <slot # > with operational software
Informational message during a successful system initialization. The status of the download
process for WAN card in slot <slot # > is identified. This should be reported after the “Bootstrap
came alive...” message for a given adapter.

DSL test failed to establish Layer 1, port=<port # >
During power up, all WAN lines undergo a test to see if Layer 1 can be established. This message
indicates a test failure. Check the wiring. If correct, contact your phone company.

Duplicate Calling Line ID <Calling line Id> detected for devices <device name> and <device name>
This message is logged at system initialization if any devices are found to share duplicate Calling
line Ids, and have no other authentication method. This problem should be corrected by adding
additional authentication method(s) to the necessary device(s).

Each mandatory connection uses xx bytes
There is not enough memory available to accommodate the system’s total capacity load. This
informational message identifies how much memory is needed to add an additional mandatory
connection.

Each optional connection uses xx bytes
There is not enough memory available to accommodate the system’s total capacity load. This
informational message identifies how much memory is needed to add an additional optional
connection.

ECP negotiation failed to converge
Verify compatible encryption parameters on each side of the link.

EDRV transmit error <error code>
An error was returned upon the software’s request to transmit a data frame. Contact your
Distributor or Customer Support.