Verifying a dedicated connection, Verifying a frame relay connection – Cabletron Systems CSX1000 User Manual

Page 356

Advertising
background image

USER’S GUIDE

356 CyberSWITCH

V

ERIFYING

A

D

EDICATED

C

ONNECTION

To verify a dedicated connection to the CyberSWITCH, the WAN lines that are connected to the
system must be available for use, and the routing option must be properly initialized.

To verify that you have a dedicated connection:

1.

View the system messages by entering the following console command:

dr

<return>

2.

Look for the following system message among the displayed messages:

Layer 1 sync not seen - Slot=<slot #> Port=<port #> Ces=<communication

endpoint suffix>

If the above message appears, a physical problem has been detected on the indicated line.
Check for a proper connection to the CyberSWITCH and to the NT1 or CIU. If the NT1 or CIU
appears to be functioning properly, call your carrier service and report the problem.

If the above message does not appear in the displayed messages, proceed to the next step.

3.

Look for the following system message among the displayed messages:

Dedicated connection to device <device name> up: Slot=<slot#>,

Port=<port #>

If the above message is displayed, the dedicated connection is functioning.

If the following message appears, the dedicated connection is not functioning.

Dedicated connection down: Slot=<slot#>, Port=<port #>

Refer to

Remote Device Connectivity

in the Problem Diagnosis chapter. Because all remote devices

that use dedicated connections are PPP devices, follow the described set-up procedure, then
skip to the step specific for

PPP devices

.

V

ERIFYING

A

F

RAME

R

ELAY

C

ONNECTION

To verify a frame relay connection to the CyberSWITCH, the WAN lines that are connected to the
System must be available for use, and the routing option must be properly initialized. To verify a
connection, the a remote device must have a connection established.

Enter the

frame relay stats

command at the administration console. If the statistics display

appears, the frame relay subsystem should be operational. If the following message is displayed,
frame relay is not configured:

No Frame Relay Accesses configured

Enter the

cs

command at the administration console. The device name for the associated PVC

should appear in the list of connected sites.

If you receive the above message, or if the device name for the associated PVC does not appear in
the list of connected sites, then refer to

Frame Relay Connections

of the Problem Diagnosis chapter.

Advertising
This manual is related to the following products: