Verifying dhcp relay agent, Verifying dhcp relay agent initialization, Verifying dhcp relay agent 378 – Cabletron Systems CSX1000 User Manual

Page 378: Verifying dhcp relay agent initialization 378, Dhcp r

Advertising
background image

USER’S GUIDE

378 CyberSWITCH

1.

Set up two systems in a back-to-back, dedicated, BRI scenario where at least one of the systems
is a PC-Platform. Configure a dedicated access between the 2 systems.

2.

The usage of a PC-platform exploits the fact that the layer 1 of a PC-based BRI board stays
active even when you exit the software. This gives us a way to simulate an end-to-end B-
channel failure. That is, the only remaining way for the other system to detect the error is via
the Link Failure Detection mechanism (there are no D-channel failures or Layer 1 failures).

3.

On the non-PC system (or either of the two if both are PC-platforms), make sure that Link
Failure Detection is enabled. Go to the

mc

screen to make sure that the dedicated connection is

up.

4.

On the PC-platform system, enter the

quit

command.

5.

On the non-PC system wait for approximately the amount time of the echo frequency
multiplied by the maximum attempts. At this time, the feature should detect the failure, and
the

mc

screen should remove the dedicated connection.

6.

Check the log for the message which indicates that a link failure has been detected.

7.

If there is a failure, refer to

WAN Line Availability

for corrective actions.

V

ERIFYING

DHCP R

ELAY

A

GENT

The following sections provide instructions to verify that the DHCP/BOOTP Relay Agent is
working properly.

V

ERIFYING

DHCP R

ELAY

A

GENT

I

NITIALIZATION

Regardless of whether or not the Relay Agent has been enabled via configuration, some
initialization processing is always performed. If this initialization is successful, there should not be
any warnings/errors written to the report log by the DHCP Relay Agent.

1.

Examine the report log. Type:

dr

<return>

2.

The

dr

command displays the system report log. Look for any messages that begin with:

[DHCP-R]

3.

The following messages indicate that errors occurred during DHCP/BOOTP Relay Agent
initialization processing:

[DHCP-R] Failed to allocated memory for transmit buffer pool

[DHCP-R] Relay Agent initialization failed

If you do not see either of these messages in the report log, the DHCP/BOOTP Relay Agent has
successfully performed its initialization processing.

If either (or both) of these messages are contained in the report log, refer to

Relay Agent

Initialization

in the Problem Diagnosis chapter.