Comtech EF Data DT-4500-A Series User Manual

Page 102

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Ethernet-based Remote Product Management

MN-DT4500A

6–16

Click [Change Configuration] to save. Otherwise, click [Reset] to revert to the previously

assigned parameters.

Mute

Use the drop-down list to select Configuration Mute Mode as On or Off, and then click [Change].

Carrier Mute Mode

Use the drop-down list to select Carrier Mute Mode as On or Off, and then click [Change].

Cold Start Mute

Use the drop-down list to select the Cold Start Mute function as On or Off, and then click

[Change].

Fault Recovery

Use the drop-down list to select the Fault Recovery function as MANUAL or AUTOMATIC, and

then click [Change].

Channel Slope Adjustment

Enter a slope value (0.0 to 1.0) in 0.1 steps. Click [Change] when done.

Serial

Interface Type: Use the drop-down list to select the operating serial mode as RS-485 or

RS-232.

Remote Address: Enter a valid remote control address from 0001 to 9999.

Baud Rate: Use the drop-down list to select the operating baud rate as 100, 2400, 4800,

9600, 19200 or 38400 baud.

Data bits – Parity – Stop Bits: Use the drop-down list to select the asynchronous character

format as:

o 8-N-1 (8 data bits, no parity, 1 stop bit)

o 7-O-2 (7 data bits, odd parity, 2 stop bits

o 7-E-2 (7 data bits, even parity, 2 stop bits).

Click [Change Serial Configuration] to save.