A.7.4 status commands, A.7.4.1 configuration status, A.7.4.2 maintenance status – Comtech EF Data DT-4500-A Series User Manual
Page 131
DT-4500-A Series Downconverters
Revision 1
Appendix A
MN-DT4500A
A–21
A.7.4 Status Commands
Status commands retrieve configuration, maintenance and alarm status in summary form.
A.7.4.1 Configuration Status
Command
Details
Configuration Status:
<DEV/RCS_'cr'
Confirmation:
>DEV/RCS_'cr'
FRE_xxxxx.xxx'cr' Frequency
ATT_yy.yy'cr'
Attenuator
TX_nnn'cr'
Transmitter - ON/OFF/COLD
ONL_nnn'cr'
Online - ON/OFF
RED_xx_yy_z'cr' See Note
CLD_nnn'cr'
Cold Start - ON/OFF
AFR_nnn'cr'
Auto Flt Recovery-ON/OFF
EXT_xxx'cr''lf']
Ext. Ref. - YES/NO
Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as
backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain (i.e. 01 to
12), else if Redundancy ON and converter selected as a chain unit xx is the converter number (01
to 12), and z = A if Auto Mode or M if Manual Mode.
A.7.4.2 Maintenance Status
Command
Details
Maintenance Status:
<DEV/RMS_'cr'
Confirmation:
>DEV/RMS_'cr'
P15_xx.x'cr'
15 Vdc Supply
P14_xx.x'cr'
14 Vdc Supply
VCC_x.x'cr'
VCC Supply
5VD_x.x'cr'
Display 5 Vdc
TEM_xx'cr'
Temperature
IFL_xx.x'cr'
IFLO Tuning
SUM_xx.x'cr'
Sum Loop Tuning
COR_xx.x'cr'
Coarse Loop Tune
FIN_xx.x'cr''lf']
Fine Loop Tuning.