B.3 Redundant Configurations

Comtech EF Data DT-4500-A Series Downconverters can be configured in several different

redundant subsystem "Daisy Chain" configurations to meet the reliability requirements of a

communication system. These configurations include:

1:1 Redundant Systems

o Single Source IF Output Configuration: The online downconverter uses an IF transfer

switch to switch the IF signal. A single switched IF output is provided to and from the

online downconverter. The transfer switches are contained in the RSM installed in the

online downconverter. When a fault occurs in the online downconverter, the RSM is de-

activated to switch out the online downconverter, and switch the IF output to the

backup downconverter. Figure B-1 depicts the cable connections between the

downconverters. Figure B-2 shows the block diagram of this 1:1 redundant

downconverter configuration.

o Dual Source IF Output Configuration: Two IF outputs, IF Output #1 (priority) and IF

Output #2, are switched in the RSM to provide redundant operation of the

downconverters. The downconverters provide two switched IF outputs, IF Output #1

(priority) and IF Output #2. If Downconverter #1 faults, Downconverter #2 backs up the

priority channel and IF Signal #2 is not operational. Figure B-5 depicts the cable

connections between the downconverters. Figure B-6 shows the block diagram of the

1:1 redundant, dual source RF input, downconverter configuration.

1:N Redundant Systems

o An IF switch in the RSM is used to switch the IF output of a faulted online

downconverter to the backup downconverter. Figure B-7 depicts the cable connections

between the downconverters. Figure B-8 shows the block diagram for this 1:N

redundant "Daisy Chain" downconverter configuration.