A.7.1.23 application identification, A.7.1.24 force reboot – Comtech EF Data DT-4500-A Series User Manual

Page 124

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Appendix A

MN-DT4500A

A–14

A.7.1.23 Application Identification

The Application Identification (AID) command allows a free form message to be created. It is

intended to identify either the satellite, transponder, beam, destination or other aspects of the

application that may be significant to operations.

The message length corresponds to capability of the LCD and is 48 characters in total. The

second line begins at character 25, therefore, blanks must be used after line 1 information in

order to space to line 2. A carriage return ends the command. Trailing blanks will be generated

to fill the LCD field. The AID display will alternate with the Equipment type display by use of the

clear function key on the front panel. The default is "AID MESSAGE".

Command

Details

Application ID:

<DEV/AID_xxxxxxx ... xxxxx'cr'

Confirmation:

>DEV/AID_'cr'

xxxxxxxxxxxxxxxxxxxxxxxx'cr'

xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf']

Retrieve ID:

<DEV/AID_'cr'

Confirmation:

>DEV/AID_'cr'

xxxxxxxxxxxxxxxxxxxxxxxx'cr'

xxxxxxxxxxxxxxxxxxxxxxxx'cr''lf']

Note: xxxxxxx ... xxxxx = Your message, maximum 48 characters.

A.7.1.24 Force Reboot

The FRB command allows the unit to be forced to reboot after five seconds. This value is write-

only.

Command

Details

Force Reboot:

<DEV/FRB_YES'cr'

Confirmation:

>DEV/FRB_YES'cr''lf']

Advertising