A.7.1.10 Baud Rate
The default baud rate is 9600.
Command
Details
Set Baud Rate:
<DEV/SBR_xxxx'cr' xxxx = 1200, 2400, 4800, 9600, 19K2, or 38K4
Confirmation:
>DEV/SBR_xxxx'cr''lf']
Retrieve Baud Rate:
<DEV/SBR_xxxx'cr'
Confirmation:
>DEV/SBR_xxxx'cr''lf']
A.7.1.11 LCD Contrast
This legacy command does not control any hardware, but its syntax is still supported to allow
backwards compatibility with existing monitor and control applications. The default LCD
contrast is 15.
Command
Details
Set Contrast:
<DEV/CON_xx'cr' xx = 0 to 30
Confirmation:
>DEV/CON_xx'cr''lf']
Retrieve Contrast:
<DEV/CON_'cr'
Confirmation:
>DEV/CON_xx'cr''lf']
A.7.1.12 LCD Brightness
This legacy command does not control any hardware, but its syntax is still supported to allow
backwards compatibility with existing monitor and control applications. The default LCD
brightness is 15.
Command
Details
Set Brightness
<DEV/LCD_xx'cr' xx = 0 to 30
Confirmation:
>DEV/LCD_xx'cr''lf']
Retrieve Brightness:
<DEV/LCD_'cr'
Confirmation:
>DEV/LCD_xx'cr''lf']
A.7.1.13 Screen Saver Mode
This legacy command does not control any hardware, but its syntax is still supported to allow
backwards compatibility with existing monitor and control applications. The default screen saver
mode is 0.
Command
Details
Set SSM:
<DEV/SSM_x'cr'
Where:
x=0 to 5
Confirmation:
>DEV/SSM_x'cr''lf']
Retrieve SSM:
<DEV/SSM_'cr'
Confirmation:
>DEV/SSM_x'cr''lf']