A.7.5 stored alarms, A.7.5.1 total stored alarms, A.7.5.2 clear all stored alarms – Comtech EF Data DT-4500-A Series User Manual

Page 136: A.7.5.3 list all alarms

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Appendix A

MN-DT4500A

A–26

A.7.5 Stored Alarms

Up to 100 alarms are date/time stamped and stored in memory as they occur. The alarm entry is

also updated with its date/time of clearance. The entry remains in memory until it is cleared by

command.

A.7.5.1 Total Stored Alarms

This command retrieves the total number of stored alarms and the time and date of the most

recent alarm.

Retrieve Total Alarms: <DEV/TSA_'cr'

Confirmation:

>DEV/TSA_TOTAL:nn'cr'

LAST:hh:mm:ss mm/dd/yy'cr''lf']

where:

nn

= 0 to 99; the 100th alarm will be ER

hh.mm.ss

= time in hour:minute:second

mm/dd/yy

= date in month/day/year

A.7.5.2 Clear All Stored Alarms

Clear Alarms:

<DEV/CAA_YES'cr'

Confirmation:

>DEV/CAA_CLEARED'cr''lf']

A.7.5.3 List All Alarms

This command retrieves a list of the stored alarms. This command is currently unavailable when

using virtual addressing mode.

List All Alarms:

<DEV/LAA_'cr'

Confirmation:

>DEV/LAA_'cr'

xx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr'

"

"

"

"

"

"

"

"

xxx yyyyyyyyyyy hh:mm:ss mm/dd/yy'cr''lf']

Where:

xx

= stored fault number

yyyyyyyyyyy

= fault description

hh:mm:ss

= fault time

mm/dd/yy

= fault date

Advertising
This manual is related to the following products: