A.7.7 command summaries, A.7.8 user remote command summary – Comtech EF Data DT-4500-A Series User Manual
Page 138
DT-4500-A Series Downconverters
Revision 1
Appendix A
MN-DT4500A
A–28
A.7.7 Command Summaries
A.7.8 User Remote Command Summary
Utility
Commands
Set Time
<DEV/TIM_hh:mm:ss'cr'
Set Date
<DEV/DAT_mm/dd/yy'cr'
Set Time Protocol
<DEV/TPE_x'cr’
Set Time Protocol IP Address
<DEV/TPS_xxx.xxx.xxx.xxx'cr’
Set Local / Remote Status
<DEV/LRS_x'cr'
Get MAC Address
<DEV/MAC_ 'cr'
Get IP Address
<DEV/IPA_'cr'
Get IP Gateway
<DEV/IPG_'cr'
Set Physical Address
<DEV/SPA_xxx'cr'
Set Baud Rate
<DEV/SBR_xxxx'cr'
Set LCD Contrast
<DEV/CON_xx'cr'
Set LCD Brightness
<DEV/LCD_xx'cr'
Set Screen Saver Mode
<DEV/SSM_x'cr'
Set Screen Saver Timeout
<DEV/SST_xx'cr'
Set VFD Brightness
<DEV/VFD_xxx'cr'
Set Reference Oscillator
<DEV/SRO_xxx'cr'
Set Converter Slope Adj.
<DEV/SSA_xxx'cr'
Get Equipment Type
<DEV/RET_'cr'
Get Part Number
<DEV/PNM_'cr'
Get Legacy Firmware Information
<DEV/FRW_'cr'
Get Firmware Information
<DEV/FRM_'cr'
Set Firmware Image
<DEV/IMG_x'cr'
Set Application ID Message
<DEV/AID_xxxxx...xxxxx'cr'
Set Force Reboot
<DEV/FRB_YES'cr'
Configuration
Commands
Set Frequency
<DEV/FRE_xxxxx.xxx'cr'
Set Attenuation
<DEV/ATT_xx.xx'cr'
Select Cold Start Mode
<DEV/CLD_xxx'cr'
Mute/Unmute Converter
<DEV/MUT_xxx'cr'
Set Carrier Mute Mode
<DEV/CMM_xxx'cr'
Set Redundant Mute Mode
<DEV/CRM_xxx'cr'
Set Fault Recovery Mode
<DEV/AFR_xxx'cr'
Set a Preset
<DEV/PGM_nn_xxxxx.xxx_yy.yy'cr'
Get All Presets
<DEV/DPS_'cr'
Clear a Preset
<DEV/CLR_nn'cr'
Select a Preset
<DEV/SEL_nn'cr'
Redundancy Mode
Commands
Select Redundancy ON/OFF
<DEV/RED_xxx’cr’
Configure Redundant Converter
<DEV/ICT_xx_yy’cr’
Select Auto/Manual Mode
<DEV/SAM_xx_y'cr'
Forced Backup Mode
<DEV/FBU_xx_y'cr'