3 config: redundancy – Comtech EF Data DT-4500-A Series User Manual

Page 77

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Front Panel Operation

MN-DT4500A

5–9

5.3.1.3

CONFIG: REDUNDANCY

1:1 Redundancy is an optional feature for the DT-4500-A. If You attempt to select any feature from

this menu branch, and either Redundancy Configuration is off or the downconverter is the primary

operating unit, the Redundancy menu branch appears as follows:

Redundancy: MODE

Otherwise:

Redundancy: MODE
Auto/Manual FORCE HSB

Use the

◄ ►

arrow keys to select MODE, Auto/Manual, FORCE, or HSB (High Speed Bus), and

then press ENTER.

Note: If any submenu is selected from this menu branch when the unit is not in Local Mode

(i.e., the unit is in either Serial or Ethernet Remote Mode), the system prompts You to switch or

Local Mode as follows:

Remote Mode: press ENTER
for local mode, or CLEAR

Operations may continue once Local Mode is established.

CONFIG: REDUNDANCY MODE

Redundancy Config = On
CONVERTER = #BU 1:01

On the top line: First, use the

◄ ►

arrow keys to navigate to the Redundancy Config

setting, and then use the

▲ ▼ arrow keys to set operation as On or Off.

On the bottom line: First, use the

◄ ►

arrow keys to navigate to the Converter Selection

setting, and then use the

▲ ▼ arrow keys to toggle the downconverter operational

preference as #BU or #01. Note the following:

With CONVERTER = #BU, the unit is set as the standby, or backup unit. This mode of

operation is indicated on the right-hand side of the bottom line as 1:01.

With CONVERTER = #01, the unit is set as the primary operating unit. The mode of

operation is indicated on the right-hand side of the bottom line as POL=1.