A.5.5 response timeout, A.5.6 bus inactivity requirement, A.6 message structure – Comtech EF Data DT-4500-A Series User Manual

Page 115: A.6.1 start character, A.6.2 device address, A.6.3 command

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Appendix A

MN-DT4500A

A–5

A.5.5 Response Timeout

A minimum of 500 milliseconds is provided before declaring a “no response” instance, at which

time the command is re-transmitted.

A.5.6 Bus Inactivity Requirement

Comtech EF Data recommends that a minimum of 50 milliseconds bus inactivity be provided by

the user between the receipt of a response from an addressed converter and issuing the next

command on the serial bus.

A.6 Message Structure

The structure of a Command, Response, or Error Message is as follows:

Start Character

Device Address

Command or Response

End of Message String

A.6.1 Start Character

The Start Character begins each message:

Example:

< Start of a user Command.

> Start of a converter response.

A.6.2 Device Address

The Device Address consists of a Physical Address or a Physical Address and an appended Virtual

Address. This document uses DEV for the generic case examples.

Example:

<3V12

A.6.3 Command

A Command is a variable length character string beginning with a forward slash “/”’ and

containing either an instruction or an instruction and data for a converter to act upon. If data is

passed by command it is appended to the instruction by an underscore “_”. If data is retrieved

by command, underscore follows the instruction, flagging the converter to supply data in a

response.