CONFIG: REMOTE (Remote Control)
Remote Control: Local
SERIAL ETHERNET
Use the
◄ ►
arrow keys to select Local, SERIAL, or ETHERNET, and then press ENTER.
CONFIG: Remote Control Local
When Remote Control: Local is selected, then remote control will be disabled. Remote
monitoring is still possible.
CONFIG: Remote Control SERIAL
Serial Mode = RS-232
Addr=001 Baud=9600 8-N-1
On the top line: To set the Serial Mode, use the
▲ ▼ arrow keys to select RS-232 or
RS-485, and then press ENTER.
On the bottom line: To edit the Serial address, first use the
◄ ►
arrow keys to navigate to
the digit to edit, and then use the
▲ ▼ arrow keys to edit the value of that digit. The valid
range of addresses is from 001 (default) to 255.
To edit the Baud Rate, first use the
◄ ►
arrow keys to navigate to the parameter, and then
use the
▲ ▼ arrow keys to select a different baud rate. Available choices are 1200, 2400,
4800, 9600 (default), 19K2, and 38K4.
To edit the asynchronous character format, first use the
◄ ►
arrow keys to navigate to the
parameter, and then use the
▲ ▼ arrow keys to select a different format. Available choices
(i.e., number of data bits; odd, even, or no parity; number of stop bits) are 8-N-1, 7-E-2, or
7-O-2.
Press ENTER when done.
CONFIG: Remote Control ETHERNET
ADDRESS GATEWAY SNMP
MAC = 00-06-B0-00-00-0F
On the bottom line: The unit MAC address is displayed here. This read-only menu shows
the. Once the MAC address has been noted, exit this menu by pressing ENTER or CLEAR.
On the top line: Use the
◄ ►
arrow keys to select the parameter to configure – ADDRESS,
GATEWAY, or SNMP – and then press ENTER to continue.