DT-4500-A Series Downconverters

Revision 1

Front Panel Operation

MN-DT4500A

5–12

5.3.2 MONITOR

Three read-only information screens provide monitoring of a number of operating voltage,

temperature and tuning parameters. Use the

▲ ▼ arrow keys to page between screens.

The following examples are provided for informational purposes only – the data displayed here

for each parameter will vary depending on the operating conditions for the system in use:

15VDC=15.6V 14VDC=14.0V

VCC=0.5V 5VDis=0.50V

Converter Temp = +30.0C

IFLO Tuning = 0.38V

Synth Tuning: Sum=0.32V

Coarse=06.0V Fine=03.5V

Press ENTER or CLEAR to continue.

5.3.3 FAULTS

CURRENT STORED

Use the

◄ ►

arrow keys to select CURRENT or STORED, and then press ENTER.

5.3.3.1

FAULTS: CURRENT

Four read-only information screens are provided to monitor a number of operating parameters

and return back whether the parameters are OK – i.e., operating within normal ranges, or FT

i.e., currently faulted. Use the

▲ ▼ arrow keys to page between screens.

The following examples are provided for information purposes only – the data displayed here

will vary depending on the operating conditions for the system in use:

Power Faults: 15VDC=OK

14VDC=OK VCC=OK ▼

IFLO Lock Detect = OK

Synth Faults: SumLD=OK

FineLD=OK CoarseLD=OK