A.7.4.6 terminal status change, A.7.4.7 packed configuration status – Comtech EF Data DT-4500-A Series User Manual

Page 133

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Appendix A

MN-DT4500A

A–23

A.7.4.6 Terminal Status Change

The TSC_ command can be used to determine if the status of the terminal has changed since it

was last polled. If any of the parameters listed in the RCS or RUS commands have changed as a

result of user front panel operations or remote operations or if any new fault condition occur

the TSC_ command will return YES. The TSC_ command will then continue to return YES until

any of the following commands are received: RCS_, RUS_, RAS_, PACRCS_, PACRUS_, or PACRAS.

Command

Details

Configuration Status:

<DEV/TSC_'cr’

Confirmation:

>DEV/TSC_nnn'cr''lf'] nnn=YES/NO

A.7.4.7 Packed Configuration Status

Configuration Status:

<DEV/PACRCS_'cr'

Confirmation:

>DEV/PACRCS_aaaabbbcdeffgghijkl'cr''lf']

where:

aaaa = # of 125kHz steps above base frequency

1

bbb

= # of 0.25 dB steps above 0.00 dB

2

c

= 1 if Transmitter ON, 0 if OFF, 2 if Cold

d

= 1 if unit ONLINE, 0 if OFFLINE

e

= 1 if Redundancy ON, else 0

ff

= converter # (01-12,BU or 00 if e = 0)

gg

= 00 if 'ff' is 00 (redundancy OFF)

gg

= chain length (01-12) if 'ff' is BU

gg

= XX if 'ff' = 01 - 12

h

= A if Auto Mode, M if Manual

3

I

= 1 if Cold Start Enabled, else 0

j

= 1 if Auto recovery enabled, else 0

k

= 1 if an Ext. Ref is present, else 0

l

= 1 if Remote Mode, 0 if Local Mode

Notes:

1.

If the converter is 1 kHz step size, this will be the number of 1 kHz steps above the base

frequency

2.

If the converter is 0.1 -dB step size, this will be the number of 0.1 -dB steps above the

base frequency

3.

If it is a backup converter, it is always ‘A’

Advertising
This manual is related to the following products: