A.7.2.7 Auto Fault Recovery

The converter output is muted automatically in the event of a detected fault. Auto Fault

Recovery, if enabled, will cause the output signal to go active (unmuted) if all faults clear. If

disabled, the output will remain muted even after all faults clear until a MUT_OFF command is

received. If Auto Fault Recovery is enabled and the converter detects the same fault more than

five times in a five minute interval (ex: multiple IFLO lock detect faults) the function reverts to

DISABLED and the converter remains muted. The default is ON.

Command

Details

Set Fault Recovery:

<DEV/AFR_xxx'cr' xxx = ON or 0FF

Confirmation:

>DEV/AFR_xxx'cr''lf']

Retrieve Status:

<DEV/AFR_'cr'

Confirmation:

>DEV/AFR_xxx'cr''lf']

A.7.2.8 Program Preset

Use this command to store up to 32 preset frequency and attenuation settings.

Command

Details

Program Preset:

<DEV/PGM_nn_xxxxx.xxx_yy.yy'cr'

Confirmation:

>DEV/PGM_nn_xxxxx.xxx_yy.yy'cr''lf']

Note: nn = Preset Number = 01 to 32.

xxxx.xxx = Frequency = RFLow to RFHigh (for example, 14000.000 to 14500.000 MHZ for Model

UT-4514).

yy.yy = Attenuator = 00.00 to 25.00.

A.7.2.9 Display All Presets

Use this command to display all of the programmed preset values.

Command

Details

Display Presets:

<DEV/DPS_'cr'

Confirmation:

>DEV/DPS_'cr'

P01 xxxxx.xxx yy.yy'cr'

to

P32 xxxxx.xxx yy.yy'cr''lf']

Where:

xxxxx.xxx = Frequency

yy.yy= Attenuator

Note: Only programmed preset numbers are returned. If no preset(s) is programmed, “No Pre-

Selects Programmed” is returned.