DT-4500-A Series Downconverters

Revision 0

Appendix B

MN-DT4500A

B–8

B.4 Redundant System Configuration

B.4.1 Redundant System Configuration Using the Front Panel

Chapter 5. FRONT PANEL OPERATION

B.4.1.1

Initial Configuration

Redundant system configuration is controlled from the downconverter’s front panel

configuration menu. Each online unit is assigned a redundancy configuration address. This

address is dependent on the location of the online downconverter with reference to the backup.

The unit closest to the backup must be Downconverter # 1. The next unit down must be

Downconverter # 2. Figure B-9 shows the appropriate entries for a 1:3 system.

REDUNDANCY-CONFIG?-ON---

-CONVERTER-#-BU---1:03--

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-01----POL-1

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-02----POL-1

POWER ON

TRANSMIT

REMOTE

ON LINE

FAULT

STORED FAULT

STATUS

REDUNDANCY-CONFIG?-ON---
-CONVERTER-#-03----POL-1

POWER ON
TRANSMIT

REMOTE

ON LINE
FAULT

STORED FAULT

STATUS

Figure B-9. Front Panel Displays

Configure the online units first, and then configure the backup unit. Redundant polling starts

when the backup is configured. If this polling starts before the online units are configured, a