Appendix b. redundant system operation, B.1 introduction to redundancy operation – Comtech EF Data DT-4500-A Series User Manual

Page 141

Advertising
background image

B–1

Appendix B. REDUNDANT

SYSTEM OPERATION

B.1 Introduction to Redundancy Operation

The Comtech EF Data DT-4500-A Series Downconverters are configured for redundant system

operation using distributed protection switching in an active "Daisy Chain" configuration.

Comtech EF Data's proprietary "Daisy Chain" configuration distributes the downconverter

protection switching functions in the downconverters. This provides a system capability to

backup from 1 to 12 online downconverters.

A High Speed Bus (HSB) provides the communications interface between the backup and online

downconverters to detect faults and reconfigure the subsystem to replace the failed

downconverter. When a faulted downconverter is removed from active operation, it is detached

from the active downconverter chain by separating the downconverter from its switch module,

leaving the active online downconverter chain intact through the switch module. The chain can

be extended without affecting the online downconverter operation.

The active "chained" downconverters in a redundancy subsystem can also be indirectly

controlled through the backup downconverter using the remote serial communication link – this

capability is discussed in Appendix A. REMOTE CONTROL.