DT-4500-A Series Downconverters

Revision 0

Appendix B

MN-DT4500A

B–9

high-speed bus fault will result. This fault should clear when configuration is completed. At this

point, control of the redundant system is performed from the backup downconverter.

In a single polarity system set “POL=1” on all online units. In a dual polarity system, where the

BU has a Polarity Switch Module (PSM) installed, configure each unit to represent the RF feed it

is connected to POL=1 or POL=2. See Figure B-7.

B.4.1.2

Automatic Configuration Verification

Figure B-10 shows the system configured for automatic (A) operation. In this mode, failure of an

online downconverter will automatically cause a switchover to the redundant unit to occur. In

the field, the simplest way to test this mode is to turn off an online unit. The AUTO/MANUAL

selection is made in the downconverter. The online units will report their status as shown in

Figure B-10.

Figure B-10. System in Auto Redundant Mode