A.7.3.2 Automatic/Manual Mode

This command provides for automatic switching by the backup converter if both units are in the

Redundancy Mode. This command is only accepted by the backup converter. If a chain converter

is set in Manual Mode, the backup converter will log the occurrence and not act upon further

information from the converter until put into Automatic Mode. The default is off.

Command

Details

Automatic Mode:

<DEV/SAM_xx_y'cr'

Confirmation:

>DEV/SAM_xx_y'cr''lf']

Automatic Status:

<DEV/SAM_xx_'cr'

Confirmation:

>DEV/SAM_xx_y'cr''lf']

Where: xx = 01 to 12, converter number

y = A for Auto; M for Manual

A.7.3.3 Backup Mode

This command allows the user to force a backup condition for maintenance and test purposes.

This command must be sent to the converter designated as the backup converter (i.e., “BU”).

When activated this command forces the backup converter to assume the state of the specified

chain converter and forces the chain converter offline.

Command

Details

Initiate a Backup:

<DEV/FBU_xx_y'cr'

Confirmation:

>DEV/FBU_xx_y'cr''lf']

Where: xx = 01 to 12, converter number

y = ‘F’ to force a backup ‘N’ to remove a backup

Retrieve Backup Status:

<DEV/FBU_'cr'

Confirmation:

>DEV/FBU_xx_zzzzz'cr''lf']

Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter

number is not displayed.

zzzzz = ‘NONE’ if no backup active

= ‘ACTIVE’ if an automatic backup has occurred

= ‘FORCED’ if a forced backup is active