A.7.1.14 Screen Saver Timeout

This legacy command does not control any hardware, but its syntax is still supported to allow

backwards compatibility with existing monitor and control applications. The default screen saver

timeout is 05.

Command

Details

Set SST:

<DEV/SST_xx'cr' xx = 00 to 99

Confirmation:

>DEV/SST_xx'cr''lf']

Retrieve SST:

<DEV/SST_'cr'

Confirmation:

>DEV/SST_xx'cr''lf']

A.7.1.15 VFD Brightness

The VFD command allows the front panel brightness to be adjusted from 0% to 100% in 25%

steps. The default VFD brightness is 100.

Command

Details

Set VFD:

<DEV/VFD_xxx'cr' xx = 000 to 100 (in 025 steps)

Confirmation:

>DEV/VFD_xxx'cr''lf']

Retrieve VFD:

<DEV/LCD_'cr'

Confirmation:

>DEV/VFD_xxx'cr''lf']

A.7.1.16 Reference Oscillator Tuning

The default reference oscillator tuning value is 087.

Command

Details

Set Oscillator:

<DEV/SRO_xxx'cr' xxx = 0 to 255

Confirmation:

>DEV/SRO_xxx'cr''lf']

Retrieve Tuning:

<DEV/SRO_'cr'

Confirmation:

>DEV/SRO_xxx'cr''lf']

A.7.1.17 Converter Slope Adjustment

The default slope adjustment value is 0.3.

Command

Details

Set Slope Adjust:

<DEV/SSA_xxx'cr' xxx = 0.0 to 1.0

Confirmation:

>DEV/SSA_xxx'cr''lf']

Retrieve Slope Adjust:

<DEV/SSA_'cr'

Confirmation:

>DEV/SSA_xxx'cr''lf']