5–13

Conv Temperature = OK

High Speed Bus = OK

Press ENTER or CLEAR to continue.

5.3.3.2

FAULTS: STORED (Stored Faults Log)

VIEW CLEAR-ALL

Use the

◄ ►

arrow keys to select View or Clear-All, and then press ENTER.

FAULTS: STORED VIEW

If View is selected and no faults exist, the system displays the following message:

No Stored Faults.

The faults log can store up to

100

faults. When a fault condition occurs, it is date- and time-

stamped, and stored in the faults log with a number assigned in the order received. The fault

information displays as per the following example:

Log05 01/23/11 09:27:15

Fault – HSB

When the fault condition clears, this is also recorded in the same fashion as the fault was

originally recorded, as shown per the following example:

Log09 01/23/11 10:45:35

Clear – HSB

The stored faults remain in memory until the CLEAR-ALL command is entered. When the

number of faults reaches 100, the 100

th

fault will display ER.

You may use the

▲ ▼ arrow key to scroll backwards or forwards through the faults log.

Press ENTER or CLEAR to return to the previous menu.

FAULTS: STORED CLEAR-ALL

Clear All Stored Faults
No Yes