This equipment contains parts and assemblies sensitive to damage by Electrostatic

Discharge (ESD). Use ESD precautionary procedures when handling the equipment.

Once opened, inspect the shipment (Figure 2-1):

Step

Task

1

Keep all shipping materials for storage or reshipment.

2

Check the packing list to ensure the shipment is complete.

3

Inspect the equipment for any possible damage incurred during shipment. Contact

the carrier and Comtech EF Data immediately to submit a damage report if damage is

evident.

4

Review this DT-4500A Series Downconverter Installation and Operation

Manual carefully to become familiar with operation.

5

Proceed to Sect. 2.2 Installing into a Rack Enclosure.

2.2

Installing into a Rack Enclosure

When mounting the DT-4500-A into a rack enclosure (Figure 2-2):

PROPER GROUNDING PROTECTION IS REQUIRED. The equipment must be

connected to the protective earth connection at all times. It is therefore imperative

that the unit is properly grounded, using the ground stud provided on the unit rear

panel, during installation, configuration, and operation.

PROPER AIR VENTILATION IS REQUIRED. In a rack system where there is high

heat discharge, provide forced-air cooling with top- or bottom-mounted fans or

blowers.

o

Make sure there is adequate clearance inside the enclosure, especially at

the side for air ventilation.

o

Air temperature inside the rack enclosure should

never

exceed 50

°

C

(122

°

F).

For information about custom rack enclosures, contact Comtech EF Data

Customer Support during normal business hours or visit Comtech EF Data’s Web

site (www.comtechefdata.com/support.asp).