4 pre-selects, 1 pre-selects: load, 2 pre-selects: program – Comtech EF Data DT-4500-A Series User Manual

Page 82

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Front Panel Operation

MN-DT4500A

5–14

If Yes is selected, the faults log is cleared and you are returned to the previous menu. However,

if there are faults present on the unit at this time, they will be re-stamped and new log entries

will be generated.

5.3.4 PRE-SELECTS

#03 LOAD PROGRAM CLEAR

03625.125 MHz 01.25 dB

You may create (program) up to 32 operating configurations, and recall them as needed. If any

pre-selects exist, use the

▲ ▼ arrow keys browse through the available pre-selects (i.e., #01

through #32), and then press ENTER.

Note: Upon initial selection – i.e., prior to the creation of any pre-selects – this menu branch

appears as follows:

#XX LOAD PROGRAM CLEAR
No Pre-Select Programmed

Use the

◄ ►

arrow keys to select one of the following actions, and then press ENTER.

Selection

Functional Description

LOAD

Recalls a previously defined pre-select from memory.

PROGRAM

Stores a defined set of operating parameters into memory for future recall.

CLEAR

Clears a previously defined pre-select from memory.

5.3.4.1

PRE-SELECTS: LOAD

Load this pre-select
Into converter? No Yes

LOAD is operable when pre-selects have previously been programmed into the unit using the

PROGRAM submenu. Use the

◄ ►

arrow keys to select No or Yes, and then press ENTER.

5.3.4.2

PRE-SELECTS: PROGRAM

Program pre-select? #XX
04200.000 MHz 01.25 dB

Select PROGRAM when it is desired to save an operational configuration for recall at a later

date.

On the top line, first use the

▲ ▼ arrow keys to navigate to the pre-select designator (#XX),

and then use the ▲ ▼ arrow keys to select a number from 01 to 32.

Advertising
This manual is related to the following products: