A.7.2 configuration commands, A.7.2.1 frequency, A.7.2.2 attenuator – Comtech EF Data DT-4500-A Series User Manual

Page 125: A.7.2.3 cold start

Advertising
background image

DT-4500-A Series Downconverters

Revision 1

Appendix A

MN-DT4500A

A–15

A.7.2 Configuration Commands

A.7.2.1 Frequency

The default RF frequency of the unit is equal to its minimum operating frequency (RF

Low

).

Command

Details

Set Frequency:

<DEV/FRE_xxxxx.xxx'cr'

Confirmation:

>DEV/FRE_xxxxx.xxx'cr''lf']

Retrieve Frequency:

<DEV/FRE_'cr'

Confirmation:

>DEV/FRE_xxxxx.xxx'cr''lf']

Note: For example, xxxx.xxx = 14000.000 to 14500.000 MHZ in 125 KHz steps for Model

UT

-

4514-A

A.7.2.2 Attenuator

The default attenuation value is 10.00 dB.

Command

Details

Set Attenuator:

<DEV/ATT_ yy.yy'cr'

Confirmation:

>DEV/ATT_yy.yy'cr'lf']

Retrieve Attenuator:

<DEV/ATT_'cr'

Confirmation:

>DEV/ATT_ yy.yy'cr''lf']

Note: yy.yy = 00.00 to 25.00 dB in 0.25 dB steps.

A.7.2.3 Cold Start

The cold start function, if enabled, mutes the output signal for a predetermined time following

Power-Up to ensure a stable reference oscillator (15 minutes). The default is OFF. This command

is disabled in redundant systems (i.e., COMMAND NOT AVAILABLE).

Command

Details

Set Cold Start:

<DEV/CLD_xxx'cr' xxx = ON or OFF

Confirmation:

>DEV/CLD_xxx'cr''lf']

Retrieve Status:

<DEV/CLD_'cr'

Confirmation:

>DEV/CLD_xxx'cr''lf']

Advertising
This manual is related to the following products: